Midmark Ritter M9 UltraClave® Automatic Sterilizer

Midmark Ritter M9 UltraClave® Automatic Sterilizer

Condition: Refurbished

Add to Quote

Description

What do you want in a sterilizer?

  • Fast and easy use for efficient instrument processing
  • Reliability and effectiveness for infection control assurance
  • Patented automatic opening door for efficient instrument drying
  • Maximum space utilization and a complimentary design for your sterilization area

Today, more than ever, you need reliable and easy to use products from a trusted partner who understands your sterilization needs. The Midmark M9 UltraClave Automatic Sterilizer was specifically designed and engineered to meet those needs. The intuitive display and simple prompts help you easily select the cycle you need…whether it is for unwrapped items, pouches, packs or handpieces. Once the sterilization process is complete, the door conveniently opens automatically and quietly to dissipate the steam and provide fast and efficient drying of your instruments. Create peace of mind by making the dental market’s leading sterilizers…the Midmark M9 autoclave is your preferred office choice.

Features

Pulse-air Removal Technology

The M9’s Steam-Flush Pressure-Pulse Air Removal System is so efficient that it can pass the air removal tests required on more complex vacuum steam autoclave systems, thus ensuring good steam penetration for those challenging loads. Plus, less complexity means better reliability and a cost effective solution for your sterilization needs.

Convenience at a Glance

The LCD display indicates cycle selected, cycle temperature and exposure time. When the cycle enters sterilization mode, the temperature, pressure, and the remaining cycle time is displayed. Remaining cycle time is also displayed in the dry mode. Note: Temperature & pressure are not displayed during dry mode.

No More Wet Instruments

Once the sterilization is complete, the door of the autoclave opens automatically and quietly to dissipate steam and dry your instruments. You’ll have dry, sterile instruments every time.

Safety Features

If the door is not closed completely or the reservoir water level is low, the LCD display will provide the appropriate message. In either case, sterilization will not continue until you’ve attended to the unit.

Ease of Draining & Filling

For ease of draining and filling, the M9’s reservoir fill port and drain tube are in the front of the unit, not on top or in back.

Optional Printer Accessory

The M9 printer accessory provides a permanent record of cycle times, temperatures and pressures during a cycle.

Self Program Controls

Programmable controls allow for creation of different cycle parameters for special sterilization needs. Programmable buttons allow you to change the following: Exposure Time (3 to 90 minutes), Temperature (230 to 275°F), Dry Time (0 to 60 minutes), or Vent (slow or fast). The #1 and #2 buttons allow you to store the change if desired.

Pre-Programed Controls

Four pre-programmed sterilization cycle controls: Unwrapped (132°C or 270°F for 3 minutes), Pouches (132°C or 270°F for 5 minutes), Packs (121°C or 250°F for 30 minutes), Handpieces (unwrapped and pouched) (132°C or 270°F for 6 minutes).

LCD Display

Indicates cycle selected, temperature and exposure time. During the cycle, the display shows messages describing status of cycle. When the cycle enters sterilization mode, remaining time is displayed as well as temperature and pressure.

Go to Top